-40%

REED Instruments R2450SD Data Logging Thermometer

$ 120.91

Availability: 53 in stock
  • MPN: R2450SD
  • Brand: REED
  • Condition: New
  • Return shipping will be paid by: Seller
  • Refund will be given as: Money back or replacement (buyer's choice)
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days

    Description

    Untitled Document
    REED Instruments R2450SD Data Logging Thermometer
    Model:
    R2450SD
    | Order No:
    R2450SD
    Real-time data logger with integrated SD memory card measures/records up to 4 separate temperature measurements simultaneously as well as temperature differential. Accepts Type K, J , R, S, E, T thermocouples and RTD probes.
    Brand:
    REED
    Model:
    R2450SD
    Order No:
    R2450SD
    Condition:
    NEW
    Description
    REED Instruments R2450SD Data Logging Thermometer
    The R2450SD features Data hold, Max/Min functions, and an easy-to-read backlit LCD display. Using a SD card (max 16GB), a user can manually record up to 99 readings or automatically by selecting a desired sampling rate from 1 to 3600 seconds. Quickly generate an Excel file with raw data, all without the use of software. Optional accessories include a tripod and AC adapter for continuous long-term monitoring on up to 4 separate channels.
    Features
    Displays up to 4 separate measurements simultaneously
    Accepts Type K, J , R, S, E, T thermocouples and RTD probes
    Temperature differential (T1-T2), Max/Min and Data hold functions
    User selectable °C, °F
    Real-time data logger with integrated SD memory card
    User selectable sampling rate from 1 to 3600 seconds
    Easy-to-read backlit LCD display
    Tripod mount for long-term monitoring
    Low battery indicator and auto shut off
    Included
    Data Logging Thermometer
    Beaded Wire Probe
    Soft Carrying Case
    Batteries
    Specifications
    Measurement Range
    Type K
    -148 to 2372°F (-100 to 1300°C)
    Type J
    -148 to 2102°F (-100 to 1150°C)
    Type T
    -148 to 752°F (-100 to 400°C)
    Type E
    -148 to 1652°F (-100 to 900°C)
    Type R
    32 to 3092°F (0 to 1700°C)
    Type S
    32 to 2732°F (0 to 1500°C)
    RTD Pt100 Ohm
    -327.9 to 1562°F (-199.9 to 850°C)
    Accuracy
    Type K
    -148.0 to -58.1°F, ±(0.4% + 1.8°F)
    -58.0 to 999.9°F, ±(0.4% + 1°F)
    1000 to 2372°F, ±(0.4% + 2°F)
    -100.0 to -50.1°C, ±(0.4% + 1°C)
    -50.0 to 999.9°C, ±(0.4% + 0.5°C)
    1000 to 1300°C, ±(0.4% + 1°C)
    Type J
    -148.0 to -58.1°F, ±(0.4% + 1.8°F)
    -58.0 to 999.9°F, ±(0.4% + 1°F)
    1000 to 2102°F, ±(0.4% + 2°F)
    -100.0 to -50.1°C, ±(0.4% + 1°C)
    -50.0 to 999.9°C, ±(0.4% + 0.5°C)
    1000 to 1150°C, ±(0.4% + 1°C)
    Type T
    -148.0 to -58.1°F, ±(0.4% + 1.8°F)
    -58.0 to 752.0°F, ±(0.4% + 1°F)
    -100.0 to -50.1°C, ±(0.4% + 1°C)
    -50.0 to 400.0°C, ±(0.4% + 0.5°C)
    Type E
    -148.0 to -58.1°F, ±(0.4% + 1.8°F)
    -58.0 to 999.9°F, ±(0.4% + 1°F)
    1000 to 1652°F, ±(0.4% + 2°F)
    -100.0 to -50.1°C, ±(0.4% + 1°C)
    -50.0 to 900.0°C, ±(0.4% + 0.5°C)
    Type R
    32 to 3092°F, ±(0.5% + 5°F)
    0 to 1700°C, ±(0.5% + 3°C)
    Type S
    32 to 2732°F, ±(0.5% + 5°F)
    0 to 1500°C, ±(0.5% + 3°C)
    RTD Pt100 Ohm
    -327.0 to 999.9°F, ±(0.4% + 1.8°F)
    1000 to 1562°F, ±(0.4% + 2°F)
    -199.9 to 850.0°C, ±(0.4% + 1°C)
    Resolution
    Type K
    0.1°F (0.1°C)
    1°F (1°C) ≥ 1000°
    Type J
    0.1°F (0.1°C)
    1°F (1°C) ≥ 1000°
    Type T
    0.1°F (0.1°C)
    Type E
    0.1°F (0.1°C)
    1°F ≥ 1000°
    Type R
    1°F (1°C)
    Type S
    1°F (1°C)
    RTD Pt100 Ohm
    0.1°F (0.1°C)
    1°F ≥ 1000°
    General Specifications
    Resolution
    0.1 or 1°F/°C
    Type
    4-Channel Thermocouple, 2-Channel RTD
    Response Time
    1x/second
    Display
    Quad Display, LCD
    Backlit Display
    Yes
    Data Hold
    Yes
    Min
    Yes
    Max
    Yes
    Differential Measurement (T1-T2)
    Yes
    Datalogging Capabilities
    Yes
    Real-Time Clock and Date Stamp
    Yes
    Selectable Sampling Rate
    Yes (1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds)
    External Memory
    Yes, expandable up to 16GB with SD card (optional)
    Auto Shut-off
    Yes (after 10 minutes/off)
    Kick Stand
    Yes
    Tripod Mountable
    Yes
    Low Battery Indicator
    Yes
    Power Supply
    6 x AA Batteries or AC Adapter (optional)
    Data Output
    Yes (RS-232)
    Product Certifications
    CE
    Operating Temperature
    32 to 122°F (0 to 50°C)
    Storage Temperature
    14 to 140°F (-10 to 60°C)
    Operating Humidity Range
    Less than 85% RH
    Dimensions
    7.0 x 2.7 x 1.8" (177 x 68 x 45mm)
    Weight
    0.6lbs (268g)
    Terms & Conditions
    Item Condition:
    Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
    Shipping:
    We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
    Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
    *Shipping Rates are for Continental US, Please Contact us for other US Destinations
    Payment:
    Currently all payments must be made directly though PayPal
    Sales Tax:
    We are required to charge sales tax in North Carolina
    Return Policy:
    If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
    Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.