DC 12V Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch
$ 6.33
- Description
- Size Guide
Description
Function 1: Timing Pick: After power, time delay relay pull T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;Function 2: Timing off: when the power relay, time delay relay disconnected T1, T1 between 0.1 seconds -270 hours adjustable, CH1 interface to a low level pulse signal, repeat the above functions;
Function 3: Timing pull off again: After power relay to not pull, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 in 0.1 seconds -270 hours between adjustable, CH1 interface to a low pulse signal, repeat the above functions;
Function 4: Timing and then pull off: After power, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, -270 hour in 0.1 seconds delay time between T1 and T2 adjustable to CH1 interface a low pulse signal, repeat the above functions;
Function 5: Infinite loop timing mode 1: After power relay to not pull, after the delay time T1 reaches the relay is energized; pull the relay off after time T2 arrives, and then repeat the above condition, the delay time T1 and T2 at 0.1 adjustable between second -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;
Function 6: Infinite loop timing mode 2: After power, immediately pull the relay delay time T1 reaches the relay off; arrive after disconnecting time T2 relay, and then repeat the above condition, the delay time T1 and T2 in 0.1 seconds adjustable between -270 hours, giving a low level pulse signal CH1 interface, you can restart the above functions;
Function 7: Finite loop timing mode 1: 5 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;
Function 8: Finite loop timing mode 2: 6, on the basis of the function, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times to CH1 interface a low pulse signal, the above functions can be re-started;
Function 9: Latching relay modes: CH1 interface to relay a low level pulse signal, relay, give a low pulse signal relay disconnected.
Function 10: Trigger relay modes: CH1 interface to a low signal relay, relay, low disappear, relay disconnected.
Function 11: Pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, the delay time relay pull T1, T1 between 0.1 seconds -270 hours adjustable, repeating a low level interface to CH1 pulse signal, repeat the above function;
Function 12: Trigger timing off: After power relay does not act, a low-level interface to CH1 pulse signal relay, the relay off delay time T1, T1 between 0.1 seconds -270 hours adjustable, repeat to CH1 interface a low pulse signal, repeat the above functions;
Function 13: Pull the trigger timing then disconnect: After power relay does not act, CH1 interface to a low level pulse signal, the delay time T1 reaches the relay is energized; pull the relay off after T2 arrival time, delay time T1 and T2 between 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;
Function 14: Disconnect and then pull the trigger timing: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; T2 arrive after disconnecting time relay, delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, repeat the above functions;
Function 15: Infinite loop timing mode 1: After power relay does not operate to a low level pulse signal CH1 interface, the delay time T1 reaches the relay is energized; pull off the relay arrival time T2, and then repeat the above condition, the extension when the time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;
Function 16: Infinite loop timing mode 2: After power relay does not act, a low-level interface to CH1 pulse signal, immediately pull the relay, the relay off delay time T1 after arrival; break time T2 after reaching relay, then repeat the above condition, the delay time between T1 and T2 in 0.1 seconds -270 hours adjustable, repeat CH1 interface to a low level pulse signal, the above functions can be re-started;
Function 17: Finite loop timing mode 1: 15 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;
Function 18: Finite loop timing mode 2: 16 on the basis of functionality, increasing the number of cycles function, this time between T1 and T2 in 0.1 seconds -9999 seconds adjustable cycles NX adjustable between 1-9999 times, repeating to CH1 interface a low pulse signal, the above functions can be re-started;