-40%

DC 12V Multifunction Delay Time Module Switch Control Relay Cycle Timer PLC Home

$ 6.9

Availability: 10 in stock
  • Package Contents: 1* Timer module
  • CH1: Input detection interface, active at high level
  • MPN: Does Not Apply
  • Refund will be given as: Money Back
  • COM: Relay public interface
  • DC-: negative pole of DC power supply
  • Return shipping will be paid by: Buyer
  • Relay output: a 3-wire interface, all interfaces are terminals
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Restocking Fee: No
  • DC +: DC power supply positive
  • Condition: New
  • Brand: unbrandeed

    Description

    Product Description
    DC 12V Multifunction Delay Time Module Switch Control Relay Cycle Timer PLC Home
    Product description:
    100% brand new and high quality
    Made of high-quality materials, durable
    Newly upgraded to version 2.0, the module functions have been increased from the previous 8 types to 18 types to meet more application requirements;
    Increase the power supply anti-reverse function, do not make mistakes because the power module is damaged;
    Use high-quality high-voltage power supply modules to replace the previous power supply, the system is more stable and reliable;
    Increase the timekeeping by 0.1 second, and the timekeeping accuracy has been upgraded from the previous 0.1 second to 0.01 second;
    Add automatic power saving function, users can customize settings
    Module interface:
    Module control terminal: There is a 3-wire interface, all interfaces are terminals, which is convenient for users to use
    DC +: DC power supply positive
    DC-: negative pole of DC power supply
    CH1: Input detection interface, active at high level
    Relay output: a 3-wire interface, all interfaces are terminals
    NO: Normally open relay interface, short circuit and open relay after COM1
    COM: Relay public interface
    NC: Normally closed relay interface, the relay before COM1 is short-circuited, after being pulled out
    Load capacity: Normally open port Maximum load capacity: DC 0-30V / 10A, AC 0-250V / 10A
    Maximum load capacity of NC port: DC 0-28V / 10A, AC 0-125V / 10A
    Module function:
    The user can display the buttons and select the following 18 functions together, can set and save the function parameters, can view the current function parameters, the time parameter setting can be adjusted at least 0.1 second, and the accuracy is better than 0.01 second. You can obtain specific settings from the dealer Described information.
    Reminder: Function 1-8 Power-on self-start function 9-18 requires a high pulse signal (high level duration is not less than 20ms, the same below) to trigger the start.
    Function 1:
    Timing pull-up: After power on, the delay relay T1, T1 can be adjusted between 0.1 second and 270 hours, to the high level pulse signal CH1 interface, repeat the above function;
    Function 2:
    Timing off: When the power relay is off, the relay off delay time T1, T1 is adjustable between 0.1 second and 270 hours, to the high level pulse signal CH1 interface, repeat the above function;
    Function 3:
    Timing to break again: After the power relay is not pulled, the delay time T1 reaches the relay; the time relay is pulled out T2 after arrival, the delay time T1 and T2 can be adjusted from the interface to CH1 within 0.1 seconds -270 hours
    High level pulse signal, repeat the above functions;
    Function 4:
    Re-pulling timing: the power relay pulls the relay immediately after the delay time T1 arrives; the off time T2 after reaching the relay is between 0.1 second and 270 hours. The delay time between T1 and T2 can be adjusted to a high level pulse signal CH1 interface, repeat the above function;
    Function 5:
    Infinite loop timing mode 1: The delay time T1 after the power relay is not pulled reaches the relay; the time relay is disconnected after the arrival of T2, and then repeats the above state, the delay time T1 and T2 can be adjusted between 0.1 seconds and -270 hours, the highest Pulse signal CH1 interface, we can restore these functions;
    Function 6:
    Infinite loop timing mode 2: After power-on, the relay is pulled up immediately, the delay time T1 reaches the relay close; after the relay reaches the close time T2, and then repeats the above state, the delay time T1 and T2 can be adjusted between 0.1 seconds and -270 hours In between, the highest pulse signal CH1 interface can restore these functions;
    Function 7:
    The function-based limited cycle timing mode 1:5, the cycle function is added, the time between T1 and T2 is adjustable between 0.1 second and 9999 seconds, the number of cycles between NX 1-9999 times that can be used by the CH1 interface is very High pulse signal, we can restore these functions;
    Function 8:
    Limited cycle timing mode 2: Based on function 6, the number of cycles is increased. This time is adjustable between T1 and T2 between 0.1 second and 9999 seconds. The number of cycles between NX 1 and 9999 of the CH1 interface is very high. Flat pulse signal, we can restore these functions;
    Function 9:
    Latching relay mode: CH1 interface, the relay relay outputs a high-level pulse signal to disconnect the relay.
    Function 10:
    Trigger relay mode: CH1 interface relay high level signal, the relay high level disappears, the relay is disconnected.
    Function 11:
    Pull trigger time: After the power relay does not work, CH1 is connected to the high-level pulse signal, the delay time relay T1, T1 is adjustable between -270 hours and 0.1 seconds, and repeats a high-level interface to the CH1 pulse signal , Repeat the above function;
    Function 12:
    Disconnect trigger sequence: After the power relay does not work, interface the high-level pulse signal CH1 to the relay. The delay time for the relay to disconnect the relays T1 and T1 at -270 hours can be adjusted between 0.1 seconds and is CH1 The interface repeats high-level pulse signals and repeats the above functions;
    Function 13:
    Pull trigger timing and then disconnect: After the power relay does not act, the interface will reach the high level pulse signal CH1, delay T1 to reach the relay; After T2 arrives, the time relay will disconnect, the delay time T1 and T2 are between -270 hours and 0.1 seconds Adjustable, and repeat for the high-level pulse signal CH1 interface, repeat the above function;
    Function 14:
    Disconnect and pull trigger timing: After the power relay does not act, the interface pulses to the high level pulse signal CH1, immediately pulls the relay, the relay closes the delay T1 after arrival; the close time T2 after the relay arrives, the delay time T1 and T2 of -270 hours Adjustable within 0.1 seconds, and repeat the above functions for the high-level pulse signal CH1 interface;
    Function 15:
    Infinite loop timing mode 1: After the power relay does not work, connect the interface to the high pulse signal CH1, delay T1 to reach the relay; delay time T1 to reach the relay. Pull down the arrival time T2 of the relay, and then repeat the above state to extend the time. When the time T1 and T2 are adjustable between -270 hours and 0.1 seconds, and the CH1 interface is repeated as a high-level pulse signal, we can restore these functions ;
    Function 16:
    Infinite loop timing mode 2: After the power relay does not operate, the interface sends a signal to the high-level pulse signal CH1, and immediately pulls the relay. After the relay arrives, it is turned off after a delay of T1; after reaching the relay, it is turned off for T2, and then repeats the above state, T1 The delay time between T2 and T2 can be adjusted from 0.1 second to 270 hours. These functions can be restored by repeating the CH1 interface as a high-level pulse signal;
    Function 17:
    Limited cycle timing mode 1: Based on function 15, increase the number of cycles function, this time is adjustable between T1 and T2 from 0.1 second to 9999 seconds, NX cycle is adjustable between 1-9999 times, repeat until the CH1 interface is high Level pulse signal, we can restore these functions;
    Function 18:
    Limited cycle timing mode 2: Increase the number of cycles based on function 16. This time is adjustable between T1 and T2 from 0.1 second to 9999 seconds, and the NX cycle is adjustable between 1-9999 times, and repeats to the CH1 interface higher Level pulse signal can restart the above functions.
    Package list:
    1 *DC 12V multifunctional self-locking relay PLC cycle timer module delay time switch
    Note:
    1.The real color of the item may be slightly different from the pictures shown on website caused by many factors such as brightness of your monitor and light brightness.
    2.Please allow slight manual measurement deviation for the data.
    Payment
    We accept payment via Paypal only.
    Payment must be completed within 5 days. If you have any problems about payment, please contact us via ebay message.
    Delivery details
    We only
    ship to confirmed Paypal addresses.
    Please comfirm that your paypal address is in line with your shipping address.
    Please kindly note that
    the c
    ombined shipping
    is not provided
    because the shipping fee is calculated by weight. Also, the each additional item means
    exactly
    the the same color and size.
    It takes about
    7
    -15 working days to US; about 10-30 working days to other countries.
    Transit time may be a little delayed because of the
    bad
    weather and customs
    inspection
    . If you
    do
    not receive your
    item
    within 30 working days since payment finished, please contact us immediately for further assistance.
    Contact us
    We strive for 100% customer satisfaction! Positive Feedback is very important to us. If you have any questions,
    p
    lease feel free to contact us via "Ask seller a question" . We will reply your email within 24
    working hours.